Date of sending : 2007.10.13            Filename : P77X0A2A520B320UA620.BIN
Rom-ID          : P77X0A2A520B320UA620
Type            : P77 & P77/P5
System(Control) : P77X0A2
Device(Protocol): A520B320 (Pulse/ICT004)
Judgement(Notes): UA620
Version         : V2.00
Checksum        : 529F 
Currency        : Hryvna (Ukraine)
Accepted notes  : 1(2004B2006)B2(1997B2004)B5(1997B2004)B10(1997B2004B2006)B20(1997B2003)B50(1996B2004)
                  (TOTAL: 6 bills )
Accepted ways   : 4
                  

Dip switch settings:
---------------------------------------------
SW1 (SIDE)
---------------------------------------------
1          *OFF OFF OFF OFF  ON  ON  ON  ON
2          *OFF OFF  ON  ON OFF OFF  ON  ON
3          *OFF  ON OFF  ON OFF  ON OFF  ON
    H 1   /  1   2   3   4   5  10  20  100
---------------------------------------------
4 * OFF: SLOW OUTPUT PULSE(LO=50ms/HI=300ms)
    ON : FAST OUTPUT PULSE(LO=50ms/HI=100ms)
---------------------------------------------
5 * OFF: Inhibit level Active High
    ON : Inhibit level Active Low
---------------------------------------------
6   OFF: Reject  H   1  &  H   2
  * ON : Accept  H   1  &  H   2
---------------------------------------------
7   OFF: Reject  H   5 
  * ON : Accept  H   5 
---------------------------------------------
8   OFF: Reject  H  10
  * ON : Accept  H  10
---------------------------------------------
9   OFF: Reject  H  20
  * ON : Accept  H  20
---------------------------------------------
10  OFF: Reject  H  50
  * ON : Accept  H  50 
---------------------------------------------

* Default Manufacture setting
  Note:(1)Please reset the bill acceptor after set the dip switch.
       (2)Dip switches 1 to 5 are only used for pulse protocol.

---------------------------------------------
SW2 (TOP)
---------------------------------------------
---------------------------------------|---------------------------------------
 ICT Protocol                          | Pulse Protocol
---------------------------------------|---------------------------------------
1   ON : Reserved                      | 1 * ON : Credit-Pulse Normal HIGH
    OFF: Reserved                      |     OFF: Credit-Pulse Normal LOW
---------------------------------------|---------------------------------------
2   ON : Pulse Protocol                | 2 * ON : Pulse Protocol
  * OFF: ICT Protocol                  |     OFF: ICT   Protocol 
-------------------------------------------------------------------------------
3   ON : Reserved                      | 3   ON : Harness Disable   
    OFF: Reserved                      |   * OFF: Harness Enable
---------------------------------------|---------------------------------------
4   ON : Ignore Sensor Problem (Note 1)
  * OFF: Acknowledge Sensor Problem (Note 2)
-------------------------------------------------------------------------------

* Default Manufacture setting
  Note:(1)Sensor 6 problem occurred ==>> BA will be still in working order.
          (The face LED will be Flashing in short green about 2 seconds everytime you restart BA.)
       (2)BA will stop to work when it acknowledges Sensor 6 problem occurred.
          (The face LED will be flashing in red.)